A sauna heater's breaker size and its GFCI rule come from the heater's own manual, so they change from model to model. The first evening in a new sauna starts at your electrical panel, so settle the circuit before you pay.
For a 6 kW heater, Finlandia and HUUM both list a 30 A breaker, and for 8 kW, Finlandia lists 40 A. Find your model below and get its manual to your electrician before the quote.
The GFCI rule is where the makers split. Harvia, Finlandia and HUUM advise against a GFCI on the heater circuit. Sun Home's spec sheets call for GFCI protection on its infrared cabins, but on the Pod and the Eclipse 4 its own documents differ, so ask Sun Home in writing before you order either.
In October 2026, we read the manual, spec sheet or product page behind every row, and each row links the one it quotes.
Below: your model's breaker and GFCI line, what to confirm in writing, then the picks with their links.
Each row quotes the maker's own manual, spec sheet or product page, linked in the last column. Where a maker printed no breaker size or no GFCI line, the row says so.
Find your heater, then read across to the breaker, the GFCI line and the wire.
On a phone, swipe the tables to see every column.
| Heater | Rating | Breaker, as the maker states it | GFCI, in the maker's words | Wire | Source |
|---|---|---|---|---|---|
| Harvia KIP60B | 6.0 kW, 240 V, 1 phase, 25.0 A | Harvia: "standard 2-pole breaker," no size printed. HarviaNA KIP manual (by kW, no model code): "30-amp double pole breaker" for 4.5 and 6.0 kW | No. "Do not use a ground fault circuit interrupter (GFCI)." | 10/2. HarviaNA: 8/2 past 90 feet; copper with 90 °C insulation | Harvia KIP manual, p. 14 and 21; HarviaNA KIP manual, p. 3 and 6 |
| Harvia KIP80B | 8.0 kW, 240 V, 1 phase, 33.3 A | Harvia: "standard 2-pole breaker," no size printed. HarviaNA KIP manual (by kW, no model code): "40-amp double pole breaker" for 8.0 kW | No. "Do not use a ground fault circuit interrupter (GFCI)." | 8/2; copper with 90 °C insulation | Harvia KIP manual, p. 14 and 21; HarviaNA KIP manual, p. 3 and 6 |
| Harvia Vega Compact BC19 | 1.9 kW, 120 V (15.9 A) or 240 V (8 A), 1 phase | No breaker size printed | No. "Do not connect the power feed for the heater through the RCD (residual current device)/GFI (Ground Fault Interrupter)" | 14 AWG, min. 90 °C copper; seal tight conduit, no pigtails or plugs in the sauna room | Harvia BC manual, p. 10–11 |
| Finlandia FLB-30 | 3.0 kW, 240 V, 1 phase, 12.5 A | 20 A. "Breaker must be double pole non-GFCI" | No. "DO NOT USE GROUND FAULT INTERRUPTER (GFI) ON SAUNA HEATER BREAKER" | 12 | Finlandia FLB manual, p. 2, 5 and 6 |
| Finlandia FLB-45 | 4.5 kW, 240 V, 1 phase, 18.8 A | 30 A, double pole non-GFCI | No. Same p. 2 line | 10 | Finlandia FLB manual, p. 2 and 5 |
| Finlandia FLB-60 | 6.0 kW, 240 V, 1 phase, 25.0 A | 30 A, double pole non-GFCI | No. Same p. 2 line | 10 | Finlandia FLB manual, p. 2 and 5 |
| Finlandia FLB-80 | 8.0 kW, 240 V, 1 phase, 33.3 A | 40 A, double pole non-GFCI | No. Same p. 2 line | 8 | Finlandia FLB manual, p. 2 and 5 |
| HUUM DROP 6 | 6 kW at 240 V, 25 A. 4.5 kW at 208 V, 21.63 A | 30 A at either voltage | Advises against. "It is recommended to connect the unit to the mains without a GFCI breaker." | Min. 10 AWG | HUUM DROP 2.0 US manual, p. 7–8 |
| HUUM DROP 7 | 7.5 kW at 240 V, 31.25 A. 5.6 kW at 208 V, 26.92 A | 40 A at 240 V, 30 A at 208 V | Advises against. Same line | Min. 8 AWG | HUUM DROP 2.0 US manual, p. 7–8 |
Harvia's current KIP manual (Y05-1516 B, dated 08/26) gives the current and cable size but no breaker size. The 30 A and 40 A figures come from the HarviaNA KIP manual on Almost Heaven's site. The HarviaNA manual lists KIP heaters by kW and does not name the KIP60B or KIP80B. Almost Heaven is part of the Harvia group, and that manual says Harvia's own manual takes precedence.
What this means for you: on a Harvia KIP, get the breaker size in writing first.
Finlandia heads its wire column "Wire Size" with no unit, and page 2 of the same manual asks for "proper A.W.G. rated wire size" and "copper wire suitable for 90°C within Sauna walls."

If your sauna arrives with its heater, check the circuit column against the heater beside it, since on a few of these rows the makers' documents disagree.
| Sauna | Heater and rating | Breaker or circuit, as the maker states it | GFCI, in the maker's words | Wire or connection | Source |
|---|---|---|---|---|---|
| Sun Home Nova 3 | HUUM DROP 6 kW, 240 V, 25 A | "Dedicated 240V / 30A circuit. Hardwired connection." | Relays HUUM. HUUM's manuals "recommend connecting the heater to the circuit without a GFCI breaker"; "where local code requires ground-fault protection on this circuit, the electrician selects the device." | "10 AWG minimum"; hardwired | Spec sheet; assembly guide v1.2, p. 7–8 |
| Sun Home Nova 6 | HUUM DROP 7.5 kW, 240 V, 31.25 A | "Dedicated 240V / 40A circuit. Hardwired connection." | Relays HUUM. Same notice as the Nova 3 | "8 AWG minimum"; hardwired | Spec sheet; assembly guide v1.2, p. 7–8 |
| Sun Home Solaris 4 | HUUM DROP 6 (6kW on the product page), 240 V, "25A draw" | "Dedicated 240V / 30A circuit, hard-wired by a licensed electrician." | Not mentioned on the spec sheet or product page. HUUM's DROP manual: "It is recommended to connect the unit to the mains without a GFCI breaker." | Not stated; hard-wired, no plug | Spec sheet; product page; HUUM DROP 2.0 US manual, p. 7–8 |
| Sun Home Solaris 6 | HUUM Hive Mini 9 (9kW on the product page), rated line "240V / 40A" | "Dedicated 240V / 40A circuit, hard-wired by a licensed electrician." HUUM's HIVE manual for the HIVE Mini 9: 50 A circuit breaker at 240 V (37.5 A); 40 A at 208 V (6.75 kW) | Not mentioned on the spec sheet or product page. HUUM's HIVE manual: "It is recommended to connect the unit to the mains without a GFCI breaker." | Not stated; hard-wired, no plug | Spec sheet; product page; HUUM HIVE US manual, p. 5–6 |
| Almost Heaven Salem (2-person barrel) | 6 kW heater, 240 V; light on a separate 110V, 15-amp plug-in | "30-amp requirement" (product page); "30 amp breaker" (FAQ) | Product page silent. The KIP manual on Almost Heaven's site: "Do not use ground fault interrupter (GFI), per UL listing and approval." (KIP heater option) | FAQ: "8/2 wire (for runs up to 90' from the breaker box use 10/2 wire)"; heater hard-wired | Product page; FAQ; KIP manual, p. 6 |
| Almost Heaven Pinnacle (4-person barrel) | 6 kW heater, 240 V; light on a separate 120V, 15-amp plug-in | "30-amp requirement" (product page); "30 amp breaker" (FAQ) | Product page silent. Same KIP manual line | Same FAQ line; heater hardwired | Product page; FAQ; KIP manual, p. 6 |
| Golden Designs Gargellen GDI-8025-01 | Hybrid: "8.0 kw Stove with built in controls" plus full-spectrum infrared | "Electrical service: 240V / 40AMP (Stove & Full Spectrum)" | Not mentioned on the product page | Not stated | Product page |
| SunRay Cayman 400D7 | "genuine 6kW Harvia electric heater"; "Power draw 8,000 watts" | Spec row "220V, 40 amp"; "Requires a dedicated 220–240V circuit, like an electric dryer"; spec sheet "8000 W · 220V, 40 amp" | Not mentioned on the page or spec sheet | Not stated | Product page; spec sheet |
| Dundalk LeisureCraft CT Elation (barrel) | 7.5 KW electric heater option | Heater guide: "Electric heaters need a dedicated 220V/40A circuit run by a licensed electrician" | Not mentioned | Not stated | Elation page; heater guide |
| Dundalk LeisureCraft CT Palmer (cabin) | "Recommended Electric Heater Size" 6 KW | Palmer spec sheet: "Requires 240v and 30-50 amp depending on the heater." Heater guide: "dedicated 220V/40A circuit" | Not mentioned | Not stated | CT Cabin page; Palmer spec sheet; heater guide |
On three rows here, the documents disagree, and each one changes the circuit you'd plan. Sun Home's Solaris 6 sheet asks for 40A, while HUUM's manual for its heater lists 50 A at 240 V. The Cayman pairs a 6 kW heater with an 8,000 watt draw, and Dundalk's Palmer sheet gives "30-50 amp depending on the heater." Plan the Solaris 6 at 50 A and the Cayman at 40 amps, and send the questions in the confirm list below before you order.

Read your cabin's row as one set: the circuit, the GFCI line and the plug all go on the electrician's list.
| Sauna | Rating | Circuit, as the maker states it | GFCI, in the maker's words | Plug or connection | Source |
|---|---|---|---|---|---|
| Sun Home Solstice 1 | 120 V, 1,350 W | "Dedicated 120V / 20A circuit." | Required. "Include a GFCI or dual-function (AFCI/GFCI) breaker; check local code." | NEMA 5-20P plug | Spec sheet |
| Sun Home Solstice 2 | 120 V, 2,006 W | "Dedicated 120V / 20A circuit." | Required. Same line | NEMA 5-20P plug | Spec sheet |
| Sun Home Solstice 3 | 120 V, 2,250 W | "Dedicated 120V / 20A circuit." | Required. Same line | NEMA 5-20P plug | Spec sheet |
| Sun Home Solstice 4 | 240 V, 2,750 W | "Dedicated 240V / 20A circuit." Installation guide: "not found in common electrical setups - may need a transformer to accommodate" | Required. Same line | NEMA 6-20P plug, NEMA 6-20R receptacle | Spec sheet; installation guide |
| Sun Home Equinox 2 | 120 V, 1,880 W, 15.67 A | "Dedicated 120V / 20A circuit." | Required. Same line on the spec sheet. The product page, owner's manual and assembly guide also call for a GFCI or dual-function breaker | NEMA 5-20P plug | Spec sheet; product page; owner's manual (Equinox 2 and 3); assembly guide, p. 2 |
| Sun Home Equinox 3 | 120 V, 2,250 W | "Dedicated 120V / 20A circuit." | Required. Same line | NEMA 5-20P plug, NEMA 5-20R receptacle | Spec sheet |
| Sun Home Eclipse 2 | 120 V, 2,820 W, 23.5 A | "Dedicated 120V / 30A circuit with GFCI protection." | Required. "GFCI protection is required: the dedicated circuit must be GFCI protected." | NEMA L5-30P twist-lock plug | Spec sheet; assembly guide |
| Sun Home Eclipse 4 | 240 V, 5,300 W, 22 A | "Dedicated 240V / 30A circuit with a GFCI breaker; check local code. Installed by a licensed electrician." | Two answers. October 6 spec sheet and owner's manual: GFCI. Assembly guide v2.2: "where your local electrical code requires GFCI protection for this receptacle location, ask your electrician to provide it at the breaker or with a device rated for 30A and the full load of the sauna." | NEMA L6-30P twist-lock plug | Spec sheet; owner's manual; assembly guide v2.2 |
| Sun Home Pod | 120 V, 1,710 W, 14.2 A | "Dedicated 120V / 20A circuit with GFCI protection." | Required. Spec sheet: "with GFCI protection." Assembly guide, p. 8: "the dedicated circuit must be GFCI protected." The product page is silent | NEMA 5-20P plug | Spec sheet; assembly guide, p. 8; product page |
| Sun Home Luminar 2 (outdoor) | 240 V, 4,800 W | "Dedicated 240V / 20A circuit with GFCI protection. Licensed electrician required." | Required. Same line | NEMA L6-20P twist-lock plug; L6-20R receptacle in a weatherproof enclosure | Spec sheet |
| Sun Home Luminar 5 (outdoor) | 240 V, 7,200 W | "Dedicated 240V / 30A circuit with GFCI protection. Licensed electrician required." | Required. Same line | NEMA L6-30P twist-lock plug; L6-30R receptacle in a weatherproof enclosure | Spec sheet |
| Almost Heaven Harmony / Elysian | 120 VAC; no wattage printed | "120VAC 15AMP Dedicated Circuit Required (2-person model)"; "120VAC 20AMP Dedicated Circuit Required (3-person model)" | Not recommended. "GFCI protected outlet/circuit breaker is not recommended" | Plug-in; no wall adapter, surge protector or extension cord | Harmony manual |
| Golden Designs DYN-6996-01 Elite | 120 V | "REQUIRES 2 SEPARATE DEDICATED 120V/20 AMP OUTLETS" | Not mentioned in the manual | Plug-in; no wall adapter, surge protector or extension cord | Manual |
| SaunaCloud Atlas One (example configuration) | 6 kW, 240 V single-phase, 25 A | Example: "Dedicated 30A breaker." SaunaCloud: "there is no universal breaker size for the Atlas One name" | Example is GFCI-protected. "The illustrated example configuration uses a dedicated 240V hardwired circuit, GFCI-protected" | Hardwired, no plug; spa disconnect recommended | Atlas One page |
| SaunaCloud Atlas Outdoor (example configuration) | 12 kW, 240 V single-phase | Example: "Circuit 60A Dedicated 240V circuit" | Example is GFCI-protected. Same wording | Hardwired; outdoor-rated spa disconnect recommended | Atlas Outdoor page |
SaunaCloud builds each sauna to a project drawing, and both Atlas pages say the electrical figures belong to an illustrated example. Your proposal and electrical plans set the circuit for your build.
Checkpoint: the circuit your panel can give the sauna. If a dedicated 120V/20A circuit is the most you can add, your list is Sun Home's Solstice 1 to 3, Equinox 2 and 3 and Pod, plus Almost Heaven's 2- and 3-person Harmony. On 240 V, the amps decide: a 30 A circuit covers the FLB-60, the DROP 6, Almost Heaven's barrels and, once Harvia confirms it, the KIP60B, while the Cayman plans at 40 A. Settle this first.
It depends on the maker and the model.
On the traditional side, Harvia's KIP manual says "Do not use a ground fault circuit interrupter (GFCI)," and Finlandia's FLB table says the breaker "must be double pole non-GFCI." HUUM words it as a recommendation: "It is recommended to connect the unit to the mains without a GFCI breaker." Finlandia gives its reason on page 6. If a GFI is used, "the breaker will trip, and damage could result."
Sun Home goes the other way on its infrared cabins. Every Solstice and Equinox spec sheet says "Include a GFCI or dual-function (AFCI/GFCI) breaker; check local code," and the Pod, Eclipse 2 and Luminar sheets call for GFCI protection outright. Almost Heaven's Harmony infrared manual sides with the heater makers: "GFCI protected outlet/circuit breaker is not recommended."
Sun Home's traditional Nova saunas follow the heater maker. Their assembly guides pass on HUUM's advice and add that "where local code requires ground-fault protection on this circuit, the electrician selects the device."
What this means for you: take the GFCI line from your exact model's manual, even within one brand. Where local code disagrees, your inspector and licensed electrician settle it.

These are the places where one maker's documents, or two sources selling the same equipment, give different answers. Each line starts with the model or maker and what to plan on until the answer arrives in writing. If your model isn't here, we found no disagreement in its documents, so go straight to the picks.

Send the questions for your model before you order. Each one is written to paste into a message.
Read the circuit line, and treat a blank as a question for the maker.
Some figures need a second look. Sun Home's rated lines mix circuit size and draw. The Solstice 1 sheet reads "120V / 1,350W / 20A," and 1,350 W at 120 V is about 11 A by our arithmetic, so that 20A is the circuit. Give your electrician both figures.
A "not mentioned" GFCI cell means the document is silent, which tells you nothing either way. We did not turn a current draw into a breaker size or apply a code rule to fill a gap.
The wire sizes are what each maker prints for its own assumptions. A long run can call for heavier wire, as the HarviaNA manual's 90-foot note shows. Our home sauna electrical guide covers long runs along with panel capacity and permits.
Your local authority, usually the building department or an electrical inspector, and a licensed electrician make that call. Whether your circuit needs ground-fault protection, and which breaker and conductor go on it, depends on the code your jurisdiction enforces and on the installation instructions for the listed equipment.
Bring the manual for your exact model to both, and raise any conflict between the manual and local code before the wire is run. Hand your electrician this list:
Picture a cold evening in late fall, with the yard already dark. The barrel stands where you measured, and its 30 amp breaker has a fresh label in the panel. You step in and ladle water over the stones.
Heaters sold on their own come first, then saunas that ship with one, then infrared and custom.
Finlandia's FLB manual lists the FLB-60 at 6.0 kW, 240 V and 25.0 A, on a 30 A double pole non-GFCI breaker with 10 wire. That's the breaker, the GFCI rule and the wire from the maker in one table, so your electrician can quote straight from it. SaunaKits sells Finlandia heaters.
See SaunaKits' heaters and saunas
Harvia's manual rates the KIP60B at 6.0 kW, 240 V and 25.0 A, with 10/2 wire, and says "Do not use a ground fault circuit interrupter (GFCI)." On paper it plans like the FLB-60. The difference is the breaker: Finlandia prints its 30 A, and Harvia's current manual prints none.
Confirm before you order: ask Harvia or SaunaKits which breaker the current manual intends for the KIP60B (question 1). If Harvia won't confirm it, the FLB-60 above avoids the question. Settle that question, and the KIP60B is ready to order.
Check the Harvia KIP60B at SaunaKits
HUUM's DROP 2.0 US manual lists the DROP 6 on a 30 A breaker at either voltage, with minimum 10 AWG wire. In the first table, only the HUUM rows give a breaker at 208 V as well as 240 V. Topture carries Harvia and HUUM heaters.
Compare the sauna heaters at Topture
Almost Heaven lists a "30-amp requirement" on both product pages and a "30 amp breaker" in its FAQ, for a 6 kW heater at 240 V. The light runs on a separate 15-amp plug-in, so add an outlet for it to the electrician's list. The Almost Heaven barrels above are listed at Select Saunas.
Once the heater circuit and the light's outlet are on the plan, order either barrel.
See the saunas at Select Saunas
SunRay sells the Cayman with a "genuine 6kW Harvia electric heater with stones," and its spec row reads "220V, 40 amp." The page says it "Requires a dedicated 220–240V circuit, like an electric dryer."
Confirm before you order: ask SunRay or SaunaKits which heater ships (question 5), and plan around the 40 amp line until they answer. Once they answer, order it with the circuit already planned.
Check the SunRay Cayman at SaunaKits
Sun Home's spec sheets list a "Dedicated 120V / 20A circuit" with a NEMA 5-20P plug for the Solstice 1 to 3 and the Equinox 2 and 3. The cabin plugs in, so the electrician's list is one dedicated circuit with a GFCI or dual-function breaker. On the Equinox 2, all four Sun Home documents in its row agree on that breaker.
Read the sheet for your model, since the GFCI wording differs between its infrared and traditional lines. No Solstice or Equinox row is on the disagreement list. For the Solstice 1 to 3 and the Equinox 3, the spec sheet is the one document in the row, so go over it with your electrician before you order.
SaunaCloud builds custom infrared saunas, so the circuit comes from your design's proposal and electrical plans.
So get the circuit for your design in writing before your electrician quotes. That's question 7 above. With it in hand, you're ordering a sauna drawn for your room.
See SaunaCloud's custom infrared saunas
The circuit follows the heater, so size the heater first.
Do infrared saunas need GFCI protection?
It depends on the maker. Sun Home's spec sheets call for a GFCI or dual-function (AFCI/GFCI) breaker on the Solstice and Equinox, and for GFCI protection on the Pod, Eclipse 2 and Luminar. Almost Heaven's Harmony manual says "GFCI protected outlet/circuit breaker is not recommended." Golden Designs' DYN-6996-01 manual does not mention GFCI. Follow the manual for your exact model, and let your electrician and inspector settle any conflict with local code.
What size breaker does a 6 kW or 8 kW sauna heater need?
For a 6 kW heater, Finlandia's FLB-60 and HUUM's DROP 6 each list a 30 A breaker, and the HarviaNA KIP manual lists a 30-amp double pole breaker for 6.0 kW KIP heaters (it gives no model code). For 8 kW, Finlandia's FLB-80 and the HarviaNA manual both list 40 A. Harvia's own current KIP manual calls for "a standard 2-pole breaker" and prints no size. Use the figure in the manual for your exact heater.
What size wire does a sauna heater need?
For a 6 kW heater the heater makers land on 10-gauge (Harvia KIP 10/2, Finlandia FLB-60 10, HUUM DROP 6 minimum 10 AWG). For 8 kW, Harvia lists 8/2 and Finlandia lists 8. Harvia and Finlandia both call for copper wire rated for 90 °C inside the sauna. The HarviaNA KIP manual recommends 8/2 instead of 10/2 for a 6 kW KIP when the run is longer than 90 feet.
Why does a sauna heater trip a GFCI?
Finlandia and Harvia both warn about it. Finlandia's FLB manual says that if a GFI is used, "the breaker will trip, and damage could result." The HarviaNA KIP manual says "Using GFI will cause damage to the heater." Sun Home's Nova guides say heating elements of this type "can trip a GFCI device during normal operation." If yours trips, have a licensed electrician check the circuit against the heater's manual.
Tonight, photograph your electrical panel and measure from it to where the sauna will stand, for your electrician's list.
Before you shop, take the thirteen measurements in the free planner, which notes the manufacturer specs and code references that apply to each.
Get the free Home Performance Room Planner →
We read the makers' and sellers' documents cited above, checked October 2026, and did not test these saunas or heaters. This is general information, not electrical or code advice, so follow your model's installation instructions and have a licensed electrician do the work. Home Performance Guide earns a commission on our SaunaKits, Select Saunas, Topture, Sun Home and SaunaCloud links, at no extra cost to you. Other makers' links, and Sun Home's own documents and product pages, earn us nothing (affiliate disclosure, editorial standards).
Get the Room Planner.
Thirteen measurements to take before you buy sauna or recovery equipment, with the manufacturer specs and code references behind each one. Free. Planning a golf simulator instead? There is a twelve-measurement golf planner too.
ABOUT
Verified buyer guides for home sauna, cold plunge and recovery equipment. Specs from the manufacturers, not from other blogs.